Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Braz. j. med. biol. res ; 53(1): e9136, Jan. 2020. tab, graf
Article in English | LILACS | ID: biblio-1055487

ABSTRACT

The aim of this study was to investigate the influence of enhanced external counterpulsation (EECP) on the cardiac function of beagle dogs after prolonged ventricular fibrillation. Twenty-four adult male beagles were randomly divided into control and EECP groups. Ventricular fibrillation was induced in the animals for 12 min, followed by 2 min of cardiopulmonary resuscitation. They then received EECP therapy for 4 h (EECP group) or not (control group). The hemodynamics was monitored using the PiCCO2 system. Blood gas and hemorheology were assessed at baseline and at 1, 2, and 4 h after return of spontaneous circulation (ROSC). The myocardial blood flow (MBF) was quantified by 18F-flurpiridaz PET myocardial perfusion imaging at baseline and 4 h after ROSC. Survival time of the animals was recorded within 24 h. Ventricular fibrillation was successfully induced in all animals, and they achieved ROSC after cardiopulmonary resuscitation. Survival time of the control group was shorter than that of the EECP group [median of 8 h (min 8 h, max 21 h) vs median of 24 h (min 16 h, max 24 h) (Kaplan Meyer plot analysis, P=0.0152). EECP improved blood gas analysis findings and increased the coronary perfusion pressure and MBF value. EECP also improved the cardiac function of Beagles after ROSC in multiple aspects, significantly increased blood flow velocity, and decreased plasma viscosity, erythrocyte aggregation index, and hematocrit levels. EECP improved the hemodynamics of beagle dogs and increased MBF, subsequently improving cardiac function and ultimately improving the survival time of animals after ROSC.


Subject(s)
Animals , Male , Dogs , Counterpulsation/methods , Cardiopulmonary Resuscitation/methods , Hemodynamics/physiology , Case-Control Studies , Disease Models, Animal , Kaplan-Meier Estimate
2.
Korean Journal of Radiology ; : 709-718, 2019.
Article in English | WPRIM | ID: wpr-741461

ABSTRACT

OBJECTIVE: To investigate the association of myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) with troponin level and left ventricle (LV) function in patients with ST-segment elevated myocardial infarction (STEMI). MATERIALS AND METHODS: Thirty-five STEMI patients who successfully had undergone reperfusion treatment within 1 week of their infarction were consecutively enrolled. All patients were referred for dynamic CT-MPI. Serial high-sensitivity troponin T (hs-TnT) levels and left ventricular ejection fraction (LVEF) measured by echocardiography were recorded. Twenty-six patients with 427 segments were included for analysis. Various quantitative parameters derived from dynamic CT-MPI were analyzed to determine if there was a correlation between hs-TnT levels and LVEF on admission and again at the 6-month mark. RESULTS: The mean radiation dose for dynamic CT-MPI was 3.2 ± 1.1 mSv. Infarcted territories had significantly lower MBF (30.5 ± 7.4 mL/min/100 mL versus 73.4 ± 8.1 mL/min/100 mL, p < 0.001) and myocardial blood volume (MBV) (2.8 ± 0.9 mL/100 mL versus 4.2 ± 1.1 mL/100 mL, p = 0.044) compared with those of reference territories. MBF showed the best correlation with the level of peak hs-TnT (r = −0.682, p < 0.001), and MBV showed a moderate correlation with the level of peak hs-TnT (r = −0.437, p = 0.026); however, the other parameters did not show any significant correlation with hs-TnT levels. As for the association with LV function, only MBF was significantly correlated with LVEF at the time of admission (r = 0.469, p = 0.016) and at 6 months (r = 0.585, p = 0.001). CONCLUSION: MBF quantified by dynamic CT-MPI is significantly inversely correlated with the level of peak hs-TnT. In addition, patients with lower MBF tended to have impaired LV function at the time of their admission and at 6 months.


Subject(s)
Humans , Blood Volume , Echocardiography , Heart Ventricles , Infarction , Myocardial Infarction , Myocardial Perfusion Imaging , Reperfusion , Stroke Volume , Troponin T , Troponin
3.
Journal of Cardiovascular Ultrasound ; : 64-67, 2016.
Article in English | WPRIM | ID: wpr-89905

ABSTRACT

We performed real-time myocardial contrast echocardiography on a patient with cardiac amyloidosis and previous normal coronary angiography presenting with atypical chest pain to assess myocardial blood flow reserve (MBFR). Myocardial contrast echocardiography was performed and flash microbubble destruction and replenishment analysis was used to calculate myocardial blood flow. Dipyridamole was used to achieve hyperemia. MBFR was derived from the ratio of peak myocardial blood flow at hyperemia and rest. The results show a marked reduction in MBFR in our patient. Previous reports of luminal obstruction of intramyocardial rather than epicardial vessels by amyloid deposition may be causing microvascular dysfunction.


Subject(s)
Humans , Amyloidosis , Chest Pain , Coronary Angiography , Dipyridamole , Echocardiography , Hyperemia , Microbubbles , Phenobarbital , Plaque, Amyloid
4.
Clinics ; 70(11): 726-732, Nov. 2015. tab, graf
Article in English | LILACS | ID: lil-766153

ABSTRACT

OBJECTIVES: Perfusion abnormalities are frequently seen in Single Photon Emission Computed Tomography (SPECT) when a left bundle branch block is present. A few studies have shown decreased coronary flow reserve in the left anterior descending territory, regardless of the presence of coronary artery disease. OBJECTIVE: We sought to investigate rubidium-82 (82Rb) positron emission tomography imaging in the assessment of myocardial blood flow and coronary flow reserve in patients with left bundle branch block. METHODS: Thirty-eight patients with left bundle branch block (GI), median age 63.5 years, 22 (58%) female, 12 with coronary artery disease (≥70%; GI-A) and 26 with no evidence of significant coronary artery disease (GI-B), underwent rest-dipyridamole stress 82Rb-positron emission tomography with absolute quantitative flow measurements using Cedars-Sinai software (mL/min/g). The relative myocardial perfusion and left ventricular ejection fraction were assessed in 17 segments. These parameters were compared with those obtained from 30 patients with normal 82Rb-positron emission tomography studies and without left bundle branch block (GII). RESULTS: Stress myocardial blood flow and coronary flow reserve were significantly lower in GI than in GII (p<0.05). The comparison of coronary flow reserve between GI-A and GI-B showed that it was different from the global coronary flow reserve (p<0.05) and the stress flow was significantly lower in the anterior than in the septal wall for both groups. Perfusion abnormalities were more prevalent in GI-A (p=0.06) and the left ventricular ejection fraction was not different between GI-A and GI-B, whereas it was lower in GI than in GII (p<0.001). CONCLUSION: The data confirm that patients with left bundle branch block had decreased myocardial blood flow and coronary flow reserve and coronary flow reserve assessed by 82Rb-positron emission tomography imaging may be useful in identifying coronary artery disease in patients with left bundle branch block.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Bundle-Branch Block , Coronary Artery Disease , Coronary Circulation/physiology , Positron-Emission Tomography/methods , Bundle-Branch Block/physiopathology , Coronary Artery Disease/physiopathology , Fractional Flow Reserve, Myocardial/physiology , Myocardial Perfusion Imaging/methods , Rubidium Radioisotopes , Stroke Volume/physiology
5.
São Paulo; s.n; 2015. [133] p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: biblio-870741

ABSTRACT

Fundamento: A artéria torácica interna (ATI) "in situ" apresenta predomínio de fluxo sistólico, mas após sua anastomose no sistema coronariano esquerdo torna-se um sistema híbrido com predomínio de fluxo diastólico, sendo a relevância da patência ou não dos grandes ramos proximais da ATI anastomosada controversa quanto à possibilidade de roubo de fluxo. Porém, constata-se que durante o ecocardiograma sob estresse com dobutamina (EED), o estado funcional da ATI anastomosada pode ser avaliado através da reserva coronariana, além da verificação dos distintos efeitos no fluxo sistólico (FS), diastólico (FD) e total (FT = sistólico + diastólico). Objetivo: Verificar por meio da ecocardiografia e Doppler o efeito dos ramos proximais importantes da ATI no fluxo, na reserva de velocidade (RVFC) e de fluxo (RFC) coronariano, em pacientes com fração de ejeção do ventrículo esquerdo (FEVE) preservada (>50%). Métodos: Em ensaio clínico prospectivo controlado e randomizado, foram avaliados pacientes com (Grupo I) e sem (Grupo II), a ligadura dos ramos proximais importantes da ATI anastomosada na coronária descendente anterior. As avaliações das ATIs em nível supraclavicular e os ecocardiogramas transtorácicos foram realizados no pré-operatório, no pós-operatório precoce, seis meses após a cirurgia em condição basal e durante o EED. Neste, foi alcançada a frequência cardíaca submáxima [(220 - idade) x (0,85)] sem a ocorrência de isquemia no território subjacente à ATI anastomosada em todos os pacientes. Foram medidos o FS, o FD, o FT e o percentual de FD, nos quatro momentos do estudo. O percentual de FD resultou da divisão da integral da velocidade diastólica do fluxo pela integral da velocidade total (sistólica + diastólica) do fluxo. A reserva coronariana foi obtida através do Doppler da ATI anastomosada seis meses após a cirurgia, sendo calculada através da razão entre o valor da variável registrado no EED e em condição basal, utilizando-se para as RVFCs o pico e a...


Background: The internal thoracic artery (ITA) "in situ" has systolic flow predominance, but when grafted to the left coronary artery system, the ITA becomes a hybrid system with diastolic flow predominance. The relevance of the patency or not-patency of the large proximal branches of the ITA graft is controversial in regards to the possibility of flow steal. During dobutamine stress echocardiography (DSE), the functional status of the ITA graft can be assessed by the coronary reserve in addition to assessment of the distinct effects of DSE on systolic (SF), diastolic (DF), and total flow (TF = systolic + diastolic). Objective: To assess, by Doppler echocardiography, the effects of the significant proximal branches of ITA graft in the flow, coronary flow velocity reserve (CFVR) and coronary flow reserve (CFR), in patients with preserved (> 50%) left ventricular ejection fraction (LVEF). Methods: In a prospective randomized controlled clinical trial we evaluate patients with (Group I) and without (Group II) ligation of important proximal branches of the ITA grafted to the anterior descending coronary artery. Supraclavicular assessment of the ITAs and transthoracic echocardiograms were performed, at rest and during DSE, on pre-operative, early and six months post-operative. In all patients, the submaximal heart rate [(220 - age) x (0.85)] was achieved during DSE with no ischemia to the area matching the ITA graft. The SF, DF, TF and percentage of DF were measured in the four moments of this study. The percentage of DF was calculated by the ratio of the integral of the diastolic flow velocity by the integral of the total flow velocity (systolic + diastolic). The coronary reserve was assessed at six months post-operative, and it was calculated by the ratio of the variable during DSE and at rest, using the maximum and the mean of the diastolic flow velocity to calculate the CFVR; and the TF to calculate the CFR. Student's t-tests or Wilcoxon's rank sum test (Mann...


Subject(s)
Humans , Male , Female , Echocardiography, Doppler , Echocardiography, Stress , Fractional Flow Reserve, Myocardial , Mammary Arteries , Myocardial Revascularization
6.
Chinese Traditional Patent Medicine ; (12): 1115-1119, 2007.
Article in Chinese | WPRIM | ID: wpr-407832

ABSTRACT

AIM: To investigate the effects of Shuguan Capsule on myocardial blood flow (MBF) and myocardial oxygen consumption (MOC) in anesthetized dogs. METHODS: Coronary blood flow (CBF) of twenty-five thoracotomized dogs was detected by electromagnetic flow meter and the MBF was calculated. While the oxygen content in the artery (AO2 ) and in the coronary venous sinus (VO2) was determined with blood oxygen analysis.Moreover, the other cardiac hemodynamic parameters, such as heart rate (HR), femoral arterial blood pressure (BP), were observed by physiological polygraph. RESULTS: It was found that Shuguan Capsule (48.5 mg/kg and 194 mg/kg) could significantly increase the MBF, and then decease the coronary artery resistance. Furthermore, Shuguan Capsule could also lower the AO2, but increase the VO2, which led to the decreased MOC. CONCLUSION: Shuguan Capsule exhibits the effects to keep the balance between blood supply and oxygen consumption in the heart by modulating the coronary resistance and by reducing MOC in dogs.

7.
Nuclear Medicine and Molecular Imaging ; : 194-200, 2007.
Article in Korean | WPRIM | ID: wpr-189511

ABSTRACT

PURPOSE: 13N-ammonia is a well known radiopharmaceutical for the measurement of a myocardial blood flow (MBF) non-invasively using PET-CT. In this study, we investigated a correlation between MBF obtained from dynamic imaging and myocardial perfusion score (MPS) obtained from static imaging for usefulness of cardiac PET study. METHODS: Twelve patients (11 males, 1 female, 57.9+/-8.6 years old) with suspicious coronary artery disease underwent PET-CT scan. Dynamic scans (6 min: 5 sec X 12, 10 sec X 6, 20 sec X 3, and 30 sec X 6) were initiated simultaneously with bolus injection of 11 MBq/kg 13N-ammonia to acquire rest and stress image. Gating image was acquired during 13 minutes continuously. Nine-segment model (4 basal walls, 4 mid walls, and apex) was used for a measurement of MBF. Time activity curve of input function and myocardium was extracted from ROI methods in 9 regions for quantification. The MPS were evaluated using quantitative analysis software. To compare between 20-segment model and 9-segment model, 6 basal segments were excluded and averaged segmental scores were used. RESULTS: There are weak correlation between MBF (rest, 0.18-2.38 ml/min/g; stress, 0.40-4.95 ml/min/g) and MPS (rest 22-91%, stress, 14-90%), however the correlation coefficient between corrected MBF and MPS in rest state was higher than stress state (rest r=0.59; stress r=0.80). As a thickening increased, correlation between MBF and MPS also showed good correlation at each segments. CONCLUSIONS: Corrected and translated MPS as its characteristics using 13N-ammonia showed good correlation with absolute MBF measured by dynamic image in this study. Therefore, we showed MPS is one of good indices which reflect MBF. We anticipate PET-CT could be used as useful tool for evaluation of myocardial function in nuclear cardiac study.


Subject(s)
Female , Humans , Male , Coronary Artery Disease , Myocardium , Perfusion
8.
Korean Journal of Nuclear Medicine ; : 118-123, 2005.
Article in Korean | WPRIM | ID: wpr-109402

ABSTRACT

Positron emission tomography (PET) serves as a gold standard for noninvasive in vivo measurement of myocardial blood flow (MBF) and coronary flow reserve (CFR). CFR can be defined as the ratio of maximally vasodilated MBF over its basal flow. It is an important parameter for the evaluation of functional severity of coronary stenosis and prognositification in various diseases such as dilated cardiomyopathy. 13NH3, H215O, 82Rb are widely used radiopharmaceuticals for measuring MBF and CFR, This review introduces imaging techniques and its clinical utility. Cardiac application of PET and PET/CT is expected to be increased in near future.


Subject(s)
Cardiomyopathy, Dilated , Coronary Stenosis , Electrons , Positron Emission Tomography Computed Tomography , Positron-Emission Tomography , Radiopharmaceuticals
9.
Korean Journal of Nuclear Medicine ; : 316-326, 1999.
Article in Korean | WPRIM | ID: wpr-62351

ABSTRACT

PURPOSE: We evaluated the feasibility of extracting pure left ventricular blood pool and myocardial time-activity curves (TACs) and of generating factor images from human dynamic N-13 ammonia PET using factor analysis. The myocardial blood flow (MBF) estimates obtained with factor analysis were compared with those obtained with the user drawn region-of-interest (ROI) method. MATERIALS AND METHODS: Stress and rest N-13 ammonia cardiac PET imaging was acquired for 23 min in 5 patients with coronary artery disease using GE Advance tomograph. Factor analysis generated physiological TACs and factor images using the normalized TACs from each dixel. Four steps were involved in this algorithm: (a) data preprocessing; (b) principal component analysis; (c) oblique rotation with positivity constraints; (d) factor image computation. Area under curves and MBF estimated using the two compartment N-13 ammonia model were used to validate the accuracy of the factor analysis generated physiological TACs. The MBF estimated by factor analysis was compared to the values estimated by using the ROI method. RESULTS: MBF values obtained by factor analysis were linearly correlated with MBF obtained by the ROI method (slope=0.84, r=0.91). Left ventricular blood pool TACs obtained by the two methods agreed well (Area under curve ratio: 1.02 (0~1 min), 0.98 (0~2 min), 0.86 (1~2 min)). CONCLUSION:: The RESULTS of this study demonstrates that MBF can be measured accurately and noninvasively with dynamic N-13 ammonia PET imaging and factor analysis. This method is simple and accurate, and can measure MBF without blood sampling, ROI definition or spillover correction. KW: N-13 ammonia, PET, Myocardial blood flow, Factor analysis


Subject(s)
Humans , Ammonia , Area Under Curve , Coronary Artery Disease , Factor Analysis, Statistical , Principal Component Analysis
10.
Korean Journal of Nuclear Medicine ; : 73-82, 1997.
Article in Korean | WPRIM | ID: wpr-71658

ABSTRACT

Regional myocardial blood flow (rMBF) can be noninvasively quantified using N-13 ammonia and dynamic positron emission tomography (PET). The quantitative accuracy of the rMBF values, however, is affected by the distortion of myocardial PET images caused by finite PET image resolution and cardiac motion. Although different methods have been developed to correct the distortion typically classified as partial volume effect and spillover, the methods are too complex to employ in a routine clinical environment. We have developed a refined method incorporating a geometric model of the volume representation of a region-of-interest (ROI) into the two- compartment N-13 ammonia model. In the refined model, partial volume effect and spillover are conveniently corrected by an additional parameter in the mathematical model. To examine the accuracy of this approach, studies were performed in 9 coronary artery disease patients. Dynamic transaxial images (16 frames) were acquired with a GE AdvanceTM PET scanner simultaneous with intravenous injection of 20 mCi N-13 ammonia. rMBF was examined at rest and during pharmacologically (dipyridamole) induced coronary hyperemia. Three sectorial myocardium (septum, anterior wall and lateral wall) and blood pool time-activity curves were generated using dynamic images from manually drawn ROIs. The accuracy of rMBF values estimated by the refined method was examined by comparing to the values estimated using the conventional two-compartment model without partial volume effect correction. rMBF values obtained by the refined method linearly correlated with rMBF values obtained by the conventional method (108 myocardial segments, correlation coefficient (r)=0.88). Additionally, underestimated rMBF values by the conventional method due to partial volume effect were corrected by theoretically predicted amount in the refined method (slope(m)=1.57). Spillover fraction estimated by the two methods agreed well (r=1.00, m=0.98). In conclusion, accurate rMBF values can be efficiently quantified by t.


Subject(s)
Humans , Ammonia , Coronary Artery Disease , Hyperemia , Injections, Intravenous , Models, Theoretical , Myocardium , Positron-Emission Tomography
11.
Korean Circulation Journal ; : 105-117, 1994.
Article in Korean | WPRIM | ID: wpr-67000

ABSTRACT

BACKGROUND: Since reperfusion early after acute myocardial infarction has been demonstrated to reduce the infarct size and mortality, many drugs and interventions to reduce the reperfusion injury have been tried with limited success. Adenosine, a potent coronary vasodilator, has been reported to counteract a few mechanisms implicated with reperfusion injury, however, its effects and exact mechanisms to reduce the reperfusion injury have not been clearly elucidated. METHODS AND RESULTS: Effects of adenosine upon infarct size reduction and upon postulated mechanisms involved in the reperfusion injury such as no reflow phenomenon and neutrophil infiltration were evaluated in anesthetized open chest dog model where acute myocardial infarction was induced by 90 minute left anterior descending coronary artery occlusion followed by 240 minute reperfusion. Adenosine(3.75 mg/min) was administered intravenously for total 90 minutes from 30 minutes before reperfusion. Compared to control group(n=6), infarct area/risk area ratio was significantly lower in adenosine group(n=6)(34+12% vs. 22+/-11, p=0.04), although risk area/total left ventricular area ratio were similar in both groups. Myocardial blood flows(MBF), measured by radiolabelled microspheres, of the infarcted regions during coronary occlusion were similar in both groups, however, both subepicardial MBF(0.63+/-0.15ml/min/g vs. 0.95+/-0.31, p=0.02) and subendocardial MBF(0.45+/-0.08 ml/min/g vs. 0.69+/-0.27, p=0.02) were higher in daenosine group. Neutrophil infiltration, semiquantitatively measured under light microscope, were less severe in daenosine group,compared to control group. CONCLUSION: Intravenous adenosine administered before coronary reperfusion appears to reduce infarct size by limiting reperfusion injury through improving no reflow phenomenon and preventing neutrophil infiltration to the ischemic myocardium during reperfusion.


Subject(s)
Animals , Dogs , Adenosine , Coronary Occlusion , Coronary Vessels , Microspheres , Mortality , Myocardial Infarction , Myocardial Reperfusion , Myocardium , Neutrophil Infiltration , No-Reflow Phenomenon , Reperfusion Injury , Reperfusion , Thorax
12.
Chinese Pharmacological Bulletin ; (12)1986.
Article in Chinese | WPRIM | ID: wpr-558919

ABSTRACT

Aim To study the protective effects of hydroxysafflor yellow A(HSYA) on acute myocardial ischemia in dogs.Methods The acute ischemia models were prepared by ligation of left anterior descending(LAD) artery.The myocardial blood flow(MBF) was determined by ultrasonic doppler,the oxygen metabolism was recorded using blood-oxygen analysis,and the ET was measured with radioimmunological assay.The experiments adopted epicardiogram mapping to measure the scope and the degree of myocardial ischemia,and used quantitative histological assay to determine the size of myocardial infarction.Results HSYA was showed to obviously increase the MBF and the oxygen volume in coronary vein sinus.And the treatment could inhibit the ET release from the injured microvessels.Furthermore,HSYA could alleviate the degree of myocardial ischemia(?-ST),the scope of myocardial ischemia((N-ST),) and narrow the ischemic(area.) Conclusion HSYA was showed to inhibit the ET release,increase the MBF,improve the cardiac oxygen metabolism,and then inhibit the myocardial ischemia damage.

SELECTION OF CITATIONS
SEARCH DETAIL